Free calculator

Cable size calculator

Enter the power or current, the cable length and the allowed voltage drop. You get the minimum copper cross-section in mm², the breaker that goes with it and the cables we stock, with prices.

Input

Supply

kW
m

Maximum voltage drop

Minimum cross-section

2.5 mm²

Design current
14.5 A
Cable rating
24 A
Voltage drop
2.27% (5.2 V)
Circuit breaker
16 A

Reference values for copper cable with PVC insulation in conduit inside a wall (IEC tables). Grouped cables, high temperatures or underground runs need a larger section. Have a licensed electrician confirm.

Quick table: cable size and breaker

Cross-sectionMax. currentTypical breakerTypical use
1.5 mm²17.5 A10 ALighting
2.5 mm²24 A16 ASockets, washing machine, AC up to 18,000 BTU
4 mm²32 A20–25 AWater heater, larger AC, oven
6 mm²41 A32 AHob or cooker
10 mm²57 A40–50 AMain line of an apartment
16 mm²76 A63 AMain line of a house

Copper, PVC insulation, in conduit in a wall. Values are indicative.

Matching products: 2.5 mm²

FS17 wire 2.5 mm² for a single-phase circuit (phase, neutral and earth), sheathed cable of the same section and the 16 A breaker that protects it. Prices in Albanian lek incl. VAT, in stock in Shkodër.

Order on WhatsApp in English: pick up in Shkodër or get it delivered across Albania and to Kosovo.